SIMATIC S7-300, ANALOG INPUT SM 331, ISOLATED, 8 AI, RESOLUTION 9/12/14 BITS, U/I/THERMOCOUPLE/RESISTOR, ALARM, DIAGNOSTICS, 1X 20-POLE REMOVING/INSERTING WITH ACTIVE BACKPLANE BUS
SIMATIC S7-300, ANALOG INPUT SM 331, ISOLATED, 8 AI, RESOLUTION 9/12/14 BITS, U/I/THERMOCOUPLE/RESISTOR, ALARM, DIAGNOSTICS, 1X 20-POLE REMOVING/INSERTING WITH ACTIVE BACKPLANE BUS
SIMATIC S7-300, ANALOG OUTPUT SM 332, ISOLATED, 4 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 20-POLE, REMOVING AND INSERTING POSSIBLE WITH ACTIVE BACKPLANE BUS
SIMATIC S7-300, ANALOG OUTPUT SM 332, ISOLATED, 4 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 20-POLE, REMOVING AND INSERTING POSSIBLE WITH ACTIVE BACKPLANE BUS
SIMATIC S7-300, COUNTER MODULE FM 350-1 FOR S7-300, COUNTER FUNCTIONS UP TO 500 KHZ 1 CHANNEL FOR CONNECTION OF 5 V AND 24 V INCREMENTAL ENCODERS ISOCHRONOUS MODE; MEASURING RANGE TYPES INCL. CONFIGURATION PACKAGE ON CD
SIMATIC S7-300, COUNTER MODULE FM 350-1 FOR S7-300, COUNTER FUNCTIONS UP TO 500 KHZ 1 CHANNEL FOR CONNECTION OF 5 V AND 24 V INCREMENTAL ENCODERS ISOCHRONOUS MODE; MEASURING RANGE TYPES INCL. CONFIGURATION PACKAGE ON CD
SIMATIC S7-1500 COMPACT CPU CPU 1511C-1PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 175 KB FOR PROGRAM AND 1 MB FOR DATA, 16 DIGITAL INPUTS, 16 DIGITAL OUTPUTS, 5 ANALOG INPUTS, 2 ANALOG OUTPUTS, 6 HIGH SPEED COUNTERS, 4 HIGH SPEED OUTPUTS FOR PTO/PWM/FREQUENCY OUTPUT 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, INCL. FRONT CONNECTOR PUSH-IN, SIMATIC MEMORY CARD NECESSARY
SIMATIC S7-1500 COMPACT CPU CPU 1511C-1PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 175 KB FOR PROGRAM AND 1 MB FOR DATA, 16 DIGITAL INPUTS, 16 DIGITAL OUTPUTS, 5 ANALOG INPUTS, 2 ANALOG OUTPUTS, 6 HIGH SPEED COUNTERS, 4 HIGH SPEED OUTPUTS FOR PTO/PWM/FREQUENCY OUTPUT 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, INCL. FRONT CONNECTOR PUSH-IN, SIMATIC MEMORY CARD NECESSARY
SIMATIC S7-1500, CPU 1513-1 PN, CENTRAL PROCESSING UNIT WITH WORK MEMORY 600 KB FOR PROGRAM AND 2.5 MB FOR DATA, 1ST INTERFACE: PROFINET IRT WITH 2-PORT SWITCH, 25 NS BIT PERFORMANCE, SIMATIC MEMORY CARD REQUIRED - - APPROVALS AND CERTIFICATES ACCORDING TO ENTRY 109815653 AT SUPPORT.INDUSTRY.SIEMENS.COM TO BE CONSIDERED! - -
SIMATIC S7-1500, CPU 1513-1 PN, CENTRAL PROCESSING UNIT WITH WORK MEMORY 600 KB FOR PROGRAM AND 2.5 MB FOR DATA, 1ST INTERFACE: PROFINET IRT WITH 2-PORT SWITCH, 25 NS BIT PERFORMANCE, SIMATIC MEMORY CARD REQUIRED - - APPROVALS AND CERTIFICATES ACCORDING TO ENTRY 109815653 AT SUPPORT.INDUSTRY.SIEMENS.COM TO BE CONSIDERED! - -
SIMATIC S7-1500, CPU 1515-2 PN, CENTRAL PROCESSING UNIT WITH WORK MEMORY 1 MB FOR PROGRAM AND 4.5 MB FOR DATA, 1ST INTERFACE: PROFINET IRT WITH 2-PORT SWITCH, 2ND INTERFACE: PROFINET RT, 6 NS BIT PERFORMANCE, SIMATIC MEMORY CARD REQUIRED - - APPROVALS AND CERTIFICATES ACCORDING TO ENTRY 109817466 AT SUPPORT.INDUSTRY.SIEMENS.COM TO BE CONSIDERED! - -
SIMATIC S7-1500, CPU 1515-2 PN, CENTRAL PROCESSING UNIT WITH WORK MEMORY 1 MB FOR PROGRAM AND 4.5 MB FOR DATA, 1ST INTERFACE: PROFINET IRT WITH 2-PORT SWITCH, 2ND INTERFACE: PROFINET RT, 6 NS BIT PERFORMANCE, SIMATIC MEMORY CARD REQUIRED - - APPROVALS AND CERTIFICATES ACCORDING TO ENTRY 109817466 AT SUPPORT.INDUSTRY.SIEMENS.COM TO BE CONSIDERED! - -
SIMATIC S7-1500F, CPU 1516F-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORK MEMORY 3 MB FOR PROGRAM AND 7.5 MB FOR DATA 1ST INTERFACE: PROFINET IRT WITH 2-PORT SWITCH, 2ND INTERFACE: PROFINET RT, 3RD INTERFACE: PROFIBUS, 6 NS BIT PERFORMANCE, SIMATIC MEMORY CARD REQUIRED ****APPROVALS AND CERTIFICATES ACCORDING TO ENTRY 109817466 AT SUPPORT.INDUSTRY.SIEMENS.COM TO BE CONSIDERED! - -
SIMATIC S7-1500F, CPU 1516F-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORK MEMORY 3 MB FOR PROGRAM AND 7.5 MB FOR DATA 1ST INTERFACE: PROFINET IRT WITH 2-PORT SWITCH, 2ND INTERFACE: PROFINET RT, 3RD INTERFACE: PROFIBUS, 6 NS BIT PERFORMANCE, SIMATIC MEMORY CARD REQUIRED ****APPROVALS AND CERTIFICATES ACCORDING TO ENTRY 109817466 AT SUPPORT.INDUSTRY.SIEMENS.COM TO BE CONSIDERED! - -
SIMATIC S7-1500, CPU BUNDLE CONSISTING OF: CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0), INCLUDING C/C++ RUNTIME AND OPC UA RUNTIME LICENSE, 6 MB WORK MEMORY FOR PROGRAM AND 60 MB FOR DATA, 1ST INTERFACE: PROFINET IRT WITH 2-PORT SWITCH, 2ND INTERFACE: PROFINET RT, 3RD INTERFACE: PROFINET BASIC SERVICES, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC MEMORY CARD (MIN. 2 GB) REQUIRED
SIMATIC S7-1500, CPU BUNDLE CONSISTING OF: CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0), INCLUDING C/C++ RUNTIME AND OPC UA RUNTIME LICENSE, 6 MB WORK MEMORY FOR PROGRAM AND 60 MB FOR DATA, 1ST INTERFACE: PROFINET IRT WITH 2-PORT SWITCH, 2ND INTERFACE: PROFINET RT, 3RD INTERFACE: PROFINET BASIC SERVICES, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC MEMORY CARD (MIN. 2 GB) REQUIRED
SIMATIC S7-1500 DIGITAL INPUT MODULE, DI 16X24 V DC BA, 16 CHANNELS IN GROUPS OF 16, INPUT DELAY TYP. 3.2 MS, INPUT TYPE 3 (IEC 61131); DELIVERY INCL. FRONT CONNECTOR PUSH-IN
SIMATIC S7-1500 DIGITAL INPUT MODULE, DI 16X24 V DC BA, 16 CHANNELS IN GROUPS OF 16, INPUT DELAY TYP. 3.2 MS, INPUT TYPE 3 (IEC 61131); DELIVERY INCL. FRONT CONNECTOR PUSH-IN
SIMATIC S7-1500, DIGITAL INPUT MODULE DI 32X24 V DC HF, 32 CHANNELS IN GROUPS OF 16; OF WHICH 2 INPUTS AS COUNTERS CAN BE USED; INPUT DELAY 0.05..20 MS INPUT TYPE 3 (IEC 61131); DIAGNOSTICS; HARDWARE INTERRUPTS: FRONT CONNECTOR (SCREW TERMINALS OR PUSH-IN) TO BE ORDERED SEPARATELY
SIMATIC S7-1500, DIGITAL INPUT MODULE DI 32X24 V DC HF, 32 CHANNELS IN GROUPS OF 16; OF WHICH 2 INPUTS AS COUNTERS CAN BE USED; INPUT DELAY 0.05..20 MS INPUT TYPE 3 (IEC 61131); DIAGNOSTICS; HARDWARE INTERRUPTS: FRONT CONNECTOR (SCREW TERMINALS OR PUSH-IN) TO BE ORDERED SEPARATELY
SIMATIC S7-1500, DIGITAL OUTPUT MODULE DQ 32X24V DC/0.5A HF; 32 CHANNELS IN GROUPS OF 8; 4 A PER GROUP; SINGLE-CHANNEL DIAGNOSTICS; SUBSTITUTE VALUE, SWITCHING CYCLE COUNTER FOR CONNECTED ACTUATORS. THE MODULE SUPPORTS THE SAFETY-ORIENTED SHUTDOWN OF LOAD GROUPS UP TO SIL2 ACCORDING TO EN IEC 62061:2021 AND CATEGORY 3 / PL D ACCORDING TO EN ISO 13849-1:2015. FRONT CONNECTOR (SCREW TERMINALS OR PUSH-IN) TO BE ORDERED SEPARATELY
SIMATIC S7-1500, DIGITAL OUTPUT MODULE DQ 32X24V DC/0.5A HF; 32 CHANNELS IN GROUPS OF 8; 4 A PER GROUP; SINGLE-CHANNEL DIAGNOSTICS; SUBSTITUTE VALUE, SWITCHING CYCLE COUNTER FOR CONNECTED ACTUATORS. THE MODULE SUPPORTS THE SAFETY-ORIENTED SHUTDOWN OF LOAD GROUPS UP TO SIL2 ACCORDING TO EN IEC 62061:2021 AND CATEGORY 3 / PL D ACCORDING TO EN ISO 13849-1:2015. FRONT CONNECTOR (SCREW TERMINALS OR PUSH-IN) TO BE ORDERED SEPARATELY
SIMATIC S7-1500 ANALOG INPUT MODULE AI 8XU/I HS, 16 BIT RESOLUTION, ACCURACY 0.3% 8 CHANNELS IN GROUPS OF 8; COMMON MODE VOLTAGE 10 V; DIAGNOSTICS; HARDWARE INTERRUPTS 8 CHANNELS IN 0.0625 MS OVERSAMPLING; DELIVERY INCLUDING INFEED ELEMENT, SHIELD BRACKET AND SHIELD TERMINAL: FRONT CONNECTOR (SCREW TERMINALS OR PUSH-IN) TO BE ORDERED SEPARATELY
SIMATIC S7-1500 ANALOG INPUT MODULE AI 8XU/I HS, 16 BIT RESOLUTION, ACCURACY 0.3% 8 CHANNELS IN GROUPS OF 8; COMMON MODE VOLTAGE 10 V; DIAGNOSTICS; HARDWARE INTERRUPTS 8 CHANNELS IN 0.0625 MS OVERSAMPLING; DELIVERY INCLUDING INFEED ELEMENT, SHIELD BRACKET AND SHIELD TERMINAL: FRONT CONNECTOR (SCREW TERMINALS OR PUSH-IN) TO BE ORDERED SEPARATELY
SIMATIC DP, RS485 REPEATER FOR CONNECTION OF PROFIBUS/MPI BUS SYSTEMS WITH MAX. 31 NODES MAX. BAUD RATE 12 MBIT/S, DEGREE OF PROTECTION IP20 IMPROVED USER HANDLING
SIMATIC DP, RS485 REPEATER FOR CONNECTION OF PROFIBUS/MPI BUS SYSTEMS WITH MAX. 31 NODES MAX. BAUD RATE 12 MBIT/S, DEGREE OF PROTECTION IP20 IMPROVED USER HANDLING
SIMATIC DP, CONNECTION PLUG FOR PROFIBUS UP TO 12 MBIT/S 90° CABLE OUTLET, INSULATION DISPLACEMENT METHOD FASTCONNECT, WITHOUT PG SOCKET 15.8X 59X 35.6 MM (BXHXD)
SIMATIC DP, CONNECTION PLUG FOR PROFIBUS UP TO 12 MBIT/S 90° CABLE OUTLET, INSULATION DISPLACEMENT METHOD FASTCONNECT, WITHOUT PG SOCKET 15.8X 59X 35.6 MM (BXHXD)
SIMATIC DP, CONNECTION PLUG FOR PROFIBUS UP TO 12 MBIT/S WITH INCLINED CABLE OUTLET, 15.8X 54X 39.5 MM (WXHXD), TERMINATING RESISTOR WITH ISOLATING FUNCTION, WITH PG RECEPTACLE
SIMATIC DP, CONNECTION PLUG FOR PROFIBUS UP TO 12 MBIT/S WITH INCLINED CABLE OUTLET, 15.8X 54X 39.5 MM (WXHXD), TERMINATING RESISTOR WITH ISOLATING FUNCTION, WITH PG RECEPTACLE
SIMATIC DP, CONNECTION PLUG FOR PROFIBUS UP TO 12 MBIT/S 90° CABLE OUTLET, INSULATION DISPLACEMENT METHOD FASTCONNECT, WITH PG RECEPTACLE 15.8X 59X 35.6 MM (BXHXD)
SIMATIC DP, CONNECTION PLUG FOR PROFIBUS UP TO 12 MBIT/S 90° CABLE OUTLET, INSULATION DISPLACEMENT METHOD FASTCONNECT, WITH PG RECEPTACLE 15.8X 59X 35.6 MM (BXHXD)
SCALANCE XB008 UNMANAGED INDUSTRIAL ETHERNET SWITCH FOR 10/100 MBIT/S; FOR SETTING UP SMALL STAR AND LINE TOPOLOGIES; LED DIAGNOSTICS, IP20, 24 V AC/DC POWER SUPPLY, WITH 8X 10/100 MBIT/S TWISTED PAIR PORTS WITH RJ45 SOCKETS; MANUAL AVAILABLE AS A DOWNLOAD .
SCALANCE XB008 UNMANAGED INDUSTRIAL ETHERNET SWITCH FOR 10/100 MBIT/S; FOR SETTING UP SMALL STAR AND LINE TOPOLOGIES; LED DIAGNOSTICS, IP20, 24 V AC/DC POWER SUPPLY, WITH 8X 10/100 MBIT/S TWISTED PAIR PORTS WITH RJ45 SOCKETS; MANUAL AVAILABLE AS A DOWNLOAD .